Release notes - i2 Analyze 4.4.6

A high level overview of the release, listing new features, the system requirements, and any known issues.

Important notices

Features

Release highlight details - Web client

Web client new icons

  • New icons have been added to address contemporary issues.


    New icons added

Chart item grouping and customization

  • Introduces the ability to group items on the chart, enhancing readability and organization. Users can collapse groups to minimize the number of items displayed, reducing visual clutter, and expand them to view the constituent items.

    Group chart items
    Minimize group

  • Group customization is also available, allowing users to modify the group label and styling. This feature supports standard chart editing capabilities, including add, edit, remove, and undo/redo actions.


    Styling a group

Label management enhancements

  • Users can now set, edit, and reset labels for chart elements and groups directly on the chart surface, allowing them to replace existing labels or revert to the default first-record-label.


    Edit a label

Importer enhancements

  • The importer has been enhanced to provide users with greater control over data import settings. Key configurable parameters now include:

    • Delimiter selection for delimiter-separated files, allowing users to specify the separator used in their data files.
    • Starting row specification, enabling users to define where data import begins within the file.
    • File encoding selection, ensuring compatibility with various data formats and character sets.

    The application will automatically attempt to make an educated guess, using available information.

  • Notes can now be added to all records during the import process, enhancing data enrichment and annotation capabilities.


    Add a note
  • The importer can auto-generate a source reference based on the data file name, which can be optionally included in imported records to improve data traceability and origin tracking.


    Add a source reference

Ribbon reorganization

  • The ribbon has been reorganized into multiple tabs, grouping related commands in a logical and intuitive manner to improve discoverability and navigation.


    Ribbon tabs

Product information

  • An "About" section has been added to the client, providing users with easy access to key information, including the client version, server version, and SDK details. This centralized location enables users to quickly gather relevant information when reporting issues to i2.


    Web client about menu link

    Web client about section

Badges

  • A badge is a small visual indicator that displays the number of chart items contained within a minimized group or the number of unified records within a chart item, allowing users to quickly identify and understand the data at a glance. To enable badge visualization, navigate to the "Charting Preferences" section in the ribbon and toggle on the "Show Badges" option.


    Show badges toggle

    Show badges for minimized group and united record
  • A new "Select United Items" command has been added, allowing users to quickly identify and select all chart items that contain multiple underlying records.


    Select united records

Release highlight details - i2 Analyze 4.4.6

No changes.

Upgrading

To ensure compatibility, i2 recommends that the i2 Analyst's Notebook desktop client and i2 Analyze server are upgraded to the latest versions at the same time.

i2 do not support mixed version deployments, but to assist with larger deployment upgrades it is possible to use the i2 Analyst's Notebook desktop client or an i2 Analyze server from a previous version with the corresponding latest versions in this release, however some functionality might not be available in these configurations. Mixed version deployments should be aligned as quickly as possible to ensure product support.

Contact i2 Support to understand which versions can be used together in the short term for an unsupported mixed version deployment.

Fixed and known issues

The issues that have been fixed in this release, and remaining known issues.

Fixed issues

Issue numberComponentIssue title
DT00493i2 AnalyzeThe printer is unable to print the entire 360 View content

Known issues in this release

Issue numberComponentIssue title
DT00503i2 AnalyzeHeadings in the Highlight Panels may become mis-aligned

Download information

Customers who have entitlement can request copies of i2 products.

For more information, see Where can I download the latest i2 products?

Operating systems - i2 Analyze Server

The following tables show the system requirements for this release, and previous releases. These system requirements should be used to ensure that the setup you are running is fully supported. Ensure that existing deployments are upgraded to currently supported versions of all the software required.

OPERATING SYSTEMSi2 Analyze 4.4.6i2 Analyze 4.4.5i2 Analyze 4.4.4i2 Analyze 4.4.3
Microsoft Windows Server 2022 Datacenter Edition
Microsoft Windows Server 2022 Essentials Edition
Microsoft Windows Server 2022 Standard Edition
Microsoft Windows Server 2019 Datacenter Edition
Microsoft Windows Server 2019 Essentials Edition
Microsoft Windows Server 2019 Standard Edition
Microsoft Windows Server 2016 Datacenter Edition
Microsoft Windows Server 2016 Essentials Edition
Microsoft Windows Server 2016 Standard Edition
Linux Red Hat Enterprise V9 and fix packs3
Linux Red Hat Enterprise V8 and fix packs3

3 Support for Red Hat Enterprise Linux (RHEL) Server on POWER Systems is restricted to IBM Db2 and SOLR as part of a distributed deployment.

Note: i2 products are supported on hardware virtualization environments that run any of the operating systems that are listed in the detailed system requirements. When you run in a virtual environment, any issues that can be replicated by i2 in a supported operating system are addressed by using the standard support policy.

Installation of Connector Designer requires x64 Linux, Docker Engine and an internet connection. See https://docs.i2group.com/as/as-connector-designer.html for full details.

Installed Software - i2 Analyze Server

INSTALLED SOFTWAREi2 Analyze 4.4.6i2 Analyze 4.4.5i2 Analyze 4.4.4i2 Analyze 4.4.3
Open Liberty 25 (25.0.0.9)---
Open Liberty 25 (25.0.0.2)--
Open Liberty 24 (24.0.0.4)-
Open Liberty 23 (23.0.0.9)
Solr 9.9-i2-patch-wmic8---
Solr 9.8.1--
Solr 9.6.1-
Solr 9.4.0
Zookeeper 3.9.4---
Zookeeper 3.9.3--
Zookeeper 3.9.2-
Zookeeper 3.8.3

8 A patched version of Solr, specifically 9.9-i2, has been included in the i2 Analyze toolkit to address the impending deprecation of WMIC support on Windows. This custom version is provided to ensure continued compatibility and functionality. Note that the Solr community plans to release version 9.10 later in the year, which will also address the WMIC support issue. However, users of the i2 Analyze toolkit do not need to take any additional action, as the patched version 9.9-i2-patch-wmic is already included.

Note: Supplied and installed by the i2 Analyze toolkit.

Supported software - i2 Analyze Server

SOFTWARE PREREQUISITESi2 Analyze 4.4.6i2 Analyze 4.4.5i2 Analyze 4.4.4i2 Analyze 4.4.3i2 Analyze 4.4.2
PostgreSQL 17 - on Amazon Relational Database Service (RDS)🆕----
PostgreSQL 17🆕----
PostgreSQL 16 - on Amazon Relational Database Service (RDS)🆕-
PostgreSQL 16🆕--
PostgreSQL 15 - on Amazon Relational Database Service (RDS)🆕
PostgreSQL 15
IBM DB2 Standard Edition 11.5
IBM DB2 Advanced Edition 11.5
IBM DB2 11.1 Workgroup, Enterprise, Advanced Workgroup, Advanced Enterprise
Microsoft SQL Server 2022🆕
Microsoft SQL Server 2019
Microsoft SQL Server 2017

Hardware - i2 Analyze Server

Hardware RequirementsMinimum
Disk space4GB
Processor2 GHz x86-64 dual-core
Memory (Application server)16GB
Memory (JVM)8GB

Note: The minimum hardware specifications specified in the table will allow customers to install and deploy i2 Analyze on a single machine using the example deployment shipped with the on-prem toolkit. Hardware specs for an optimal i2 Analyze deployment are dependant on the expected amount of data to be loaded and user usage.

Supported Browsers - Web client and Investigate client

Supported Web Browsers
Google Chrome (latest version)
Microsoft Edge (latest version)
Mozilla Firefox (latest version)
Mozilla Firefox ESR (latest version)

Language support

i2 products are tested on a number of various regional variations of operating systems. In addition they are translated into a number of different languages.

Operating system language support

i2 supports this product on the following regional versions of the supported operating systems:

Language Group/LanguageLanguage CollectionSupport Status
Western Europe and USABasic
Central EuropeBasic
BalticBasic
CyrillicBasic
TurkicBasic
ArabicComplex Script
JapaneseEast Asian
KoreanEast Asian
Traditional ChineseEast Asian
Simplified ChineseEast Asian
ThaiComplex Script
VietnameseComplex Script
GreekBasic
HebrewComplex Script
IndicComplex Script
GeorgianComplex Script
ArmenianComplex Script
DhivehiComplex Script
GalicianComplex Script
GujaratiComplex Script
KannadaComplex Script
KyrgyzComplex Script
Mongolian (Cyrillic)Complex Script
PunjabiComplex Script
SyriacComplex Script
TeluguComplex Script

Data support

i2 products support unicode data.

Translations

The following languages are supported:

Translationsi2 Analyze 4.4.6
Arabic
Brazilian Portuguese
Bulgarian 4
Czech
English
French
German
Hungarian 5
Italian
Japanese
Korean
Polish
Russian 4
Simplified Chinese
Slovak 5
Spanish
Traditional Chinese
Turkish
Ukrainian 4

4 Help available in English only.

5 The Information Store and External Searches capabilities are not translated for these languages.